The Official journal of the European Union - WIKI

<< Back To Recent Awards..


Tile

United Kingdom-Bournemouth: Cardiology services or pulmonary specialists services

OJEU Ref

013382-2020

Type

Contract awards

Date Published

2020-01-13

Nature Of Contract

Supply contract

Awarding Authority

Body goverened by public law

Awarding Criteria

The most economic tender

Procedure

Open procedure

CONTRACT AWARD



Section I: Contracting authority

I.1) Name and addresses:
Official name: The Royal Bournemouth and Christchurch hospital
National registration number: RDZ
Postal address: Castle Lane East
Town: Bournemouth
Postal code: BH7 7DW
Country: UK
Contact person: Hayley Kelly
Telephone: +44 1202726084
E-mail: hayley.kelly@rbch.nhs.uk
NUTS code: UKK21
Main address (URL): https://www.delta-esourcing.com
I.1) Name and addresses:
Official name: Poole Hospital NHS Foundation Trust
National registration number: RD3
Postal address: Longfleet Rd
Town: Poole
Postal code: BH15 2JB
Country: UK
E-mail: carl.holdsworth@poole.nhs.uk
NUTS code: UKK21
Main address (URL): https://www.delta-esourcing.com
Joint procurement
I.2) The contract involves joint procurement
I.4) Type of the contracting authority: BODY PUBLIC

Main Activity
I.5.1) Main Activity: HEALTH

Section II: Object of Contract


Title:
The Supply of Brady Pacemakers, Cardiac Resynchronisation Pacemakers and Implantable Loop Recorders
Reference number: RBCH EU 0018 10

II.1.4) Short description
Pacemakers, CRTP's and Loop Recorders
Total Value:
GBP 3852940

Information about lots
II.1.6) This contract is divided into lots: yes


Description: Item/Lot 1
Title:
Brady Pacemakers
II.2.1) Lot No: 1
NUTS code: UKK21
II.2.3.2) Main site or place of performance:
Bournemouth and Poole.
II.1.4) Short description
Brady pacemaker systems,
— P1: Dual Chamber,
— P2: Single Chamber,
— P3: Leads,
— P4: Generators only.
II.2.5) Award criteria:

Criteria: Project technical and quality weighting %
Weighting: 30
Cost/Price
Criteria: Project price weighting %
Weighting: 70



Additional information:
To respond to this opportunity please click here: https://www.delta-esourcing.com/respond/823JNUA9G5

Description: Item/Lot 2
Title:
CRTP’s (Cardiac Resynchronisation Therapy Pacemakers)
II.2.1) Lot No: 2
NUTS code: UKK21
II.2.3.2) Main site or place of performance:
Bournemouth and Poole.
II.1.4) Short description
Lot 2: Cardiac resynchronisation pacemakers systems
While functioning like a normal pacemaker to treat slow heart rhythms, a CRT-P device also delivers small electrical impulses to the left ventricle to improve the coordination of ventricular contraction. A CRT-P system consists of the pulse generator (device) and pacing leads that are in contact with the inner wall of the right atrium, the right ventricle and an additional lead positioned within the coronary sinus.
C.1 CRT-P systems
Systems offered must be MRI conditional to at least 1.5 Tesla, ideally full body.
Devices should offer a rate response option (Dual sensor or Physiological response sensor), with a maximal programmable sensor rate and ability to adjust sensitivity of response.
Devices must have options that allow minimised ventricular pacing via algorithms that allow an extension of AV delays/ability to switch from atrial based to ventricular based pacing upon detection of AV block.
Automatic self-lead checks with viewable trends and alerts for measurements outside programmed ranges.
EGM storage for events.
Rate hysteresis/night rate.
Fully programmable parameter options including range of lower/upper rates from 30-180 bpm.
Full range of pacing modes including DDD, VVI, DDI as well as those needed to meet the requirements already stated above.
Ergonomically shaped and sized, max. volume 20CC.
Ideally offer AF therapy to include rate regulation, pause suppression and overdrive pacing.
Diagnostics – must include HR graph, % pacing and HF information (e.g. rate variation, activity levels, thoracic impedance).
Estimated battery longevity > 6yrs.
Must have wireless telemetry.
Ideally compatible with home monitoring multiple options for output to include automatic selection in line with daily lead checks. Manual options to allow for output and pulse width changes ideally from <1V up to max output in increments of up to 0,5 V (increment doesn’t have to cover entire output range, but ideally up to at least 5V).
Must be an IS-1 connection for RA and RV lead and IS-4 connection for LV lead.
Must offer all available configurations for LV pacing.
Ideally offer automatic programming suggestions feature e.g. for AV/VV delays.
Programmable VV offset.
Ideally offer a threshold test feature that allows quick assessment of all programmable LV configurations.
C.2 Generators only
There will be a requirement for standalone generators to be purchased for box change procedures. These will need to be a mix of full body MRI conditional devices to maintain currently MRI compatibility and non MRI for those patients with non MRI leads. Generators must fulfil all of the other criteria above (C. 1).
CRT-P generators used for box change will need to cover all combinations of lead connectors, including IS-4 and IS-1 connections for LV leads.
C.3 Leads only
Must be IS-4 connection for LV lead.
Available in a range of shapes and lengths.
See Lot 5.1 for RA and RV leads.
II.2.5) Award criteria:

Criteria: Project technical and quality weighting (%)
Weighting: 30
Cost/Price
Criteria: Project price weighting (%)
Weighting: 70



Additional information:
To respond to this opportunity please click here: https://www.delta-esourcing.com/respond/N3TB72D72N

Description: Item/Lot 3
Title:
Loop Recorder
II.2.1) Lot No: 3
NUTS code: UKK21
II.2.3.2) Main site or place of performance:
Bournemouth and Poole.
II.1.4) Short description
Lot 3: Implantable loop recorder
An insertable Cardiac monitor that allows home ECG monitoring of patients with suspected cardiac arrhythmias or unexplained syncope.
Must be injectable.
No greater than 2CC
Record an EGM for both automatic events and patient activated episodes.
Must be able to be activated by the patient at time of symptom.
Must be supplied with remote monitoring that enables both patient activated and automatic download on detection of events.
Battery longevity of approximately 2 years.
Programmable options to allow for EGM storage pre and post activation/detection.
Programmable event criteria.
Ergonomic design.
Must be full body MRI-conditional.
5.4 Implant Accessories
The following must be provided:
Peel-able Introducer sheaths in a range of sizes from 6Fr – 9Fr
Testing cables
LV Introducer sheaths (outer and inner)
Lead end caps
Pin port plugs
Stylets
Wrench kit
Rotation Tool
LV guide wire
IS-4 connector tool (where applicable)
LV sheath slitter
Balloon occlusion catheter
ID card holders ideally
II.2.5) Award criteria:

Criteria: Project technical and quality weighting (%)
Weighting: 30
Cost/Price
Criteria: Project price weighting (%)
Weighting: 70



Section IV: Procedure

IV.1.1) Type of procedure: Open


Contract No:
2019/S 130-318552
II.2.1) Lot No: 1
Title:
Brady Pacemakers

2020-01-01

5
0
0
0
5




Official name: Abbott Medical UK Ltd
Postal address: Elder House, Blythe Valley Business Park, Central Boulevard
Town: Solihul
Postal code: B90 8AJ
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no


Official name: Biotronik UK Ltd
National registration number: BIOTRONIK House
Postal address: Avonbury Business Park, Bicester
Town: Oxon
Postal code: OX26 2UA
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no


Official name: MicroPort CRM UK Ltd
Postal address: Willow House, Park West Business Park, Sealand Road
Town: Chester
Postal code: CH1 4RW
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no


Official name: Boston Scientific Ltd
Postal address: Breakspear Park, Breakspear Way, Hemel Hempstead
Town: Hertfordshire
Postal code: HP2 4TZ
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no

II.01) Estimated value excluding VAT:
GBP 2186300
Total Value:
GBP 2186300

II.2.1) Lot No: 2
Title:
Cardiac Resynchronisation Pacemakers

2020-01-01

5
0
0
0
5




Official name: Abbott Medical UK Ltd
Postal address: Elder House, Blythe Valley Business Park, Central Boulevard
Town: Solihul
Postal code: B90 8AJ
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no


Official name: Boston Scientific Ltd
Postal address: Breakspear Park, Breakspear Way, Hemel Hempstead
Town: Hertfordshire
Postal code: HP2 4TZ
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: yes


Official name: Medtronic Ltd
Postal address: Building 9, Croxley Park, Watford
Town: Hertfordshire
Postal code: WD18 8WW
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no

II.01) Estimated value excluding VAT:
GBP 877200
Total Value:
GBP 877200

II.2.1) Lot No: 3
Title:
Implantable Loop Recorders

2020-01-01

5
0
0
0
5




Official name: Biotronik UK Ltd
Postal address: Biotronik House, Avonbury Business Park, Bicester
Town: Oxon
Postal code: OX26 2UA
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no


Official name: Abbott Medical UK Ltd
Postal address: Elder House, Blythe Valley Business Park, Central Boulevard
Town: Solihul
Postal code: B90 8AJ
Country: UK
NUTS code: UKK21
V.2.3) The contractor is an SME: no

II.01) Estimated value excluding VAT:
GBP 789440
Total Value:
GBP 789440

Section V: Complementary information


Additional information:
The contracting authority considers that this contract may be suitable for economic operators that are small or medium enterprises (SMEs). However, any selection of tenderers will be based solely on the criteria set out for the procurement.
To view this notice, please click here:
https://www.delta-esourcing.com/delta/viewNotice.html?noticeId=462445118
GO Reference: GO-202019-PRO-15790515

Review body:
Official name: The Royal Bournemouth and Christchurch Hospitals NHS Foundation Trust
Postal address: Castle Lane East
Town: Bournemouth
Postal code: BH7 7DW
Country: UK
Telephone: +44 1202726160

Section VI

VI.05.00) Date of dispatch of this notice 2020-01-09

English Language Unavailable


85121230; 85121231; Cardiology services or pulmonary specialists services; Cardiology services;